It is now amongst the most common available means for connecting industrial electronic devices. Over time its simple and robust nature has made it a communication protocol standard.
*Modbus is a serial communications protocol which was originally designed for use with PLCs (Programmable logic controllers).
The licence free 2.4 GHz direct sequence spread spectrum (DSSS) radio telemetry technology offers high integrity, error free communications which can co-exist with other wireless technologies such as Wi-Fi, Bluetooth® and Zigbee®. With this device, Modbus serial slave devices can be seamlessly added into an existing Modbus TCP network, and Modbus TCP slaves can be made accessible to serial masters. Whether wired or wireless, single or multiple serial ports, Moxas Modbus TCP gateway solutions connect Modbus RTU, DNP3, J1939, and PROFIBUS devices to. The wireless telemetry Modbus gateway offers some simple commands available to wake, sleep, and keep awake T24 transmitters. Modbus Gateway is designed for easy integration of Modbus RTU and TCP/MQTT/SNMP networks.
The T24-GW1 uses either the standard Modbus interface RTU* protocol or a simple ASCII protocol.Ĭlick here to view & download associated free software. Please contact our expert sales team using the quick enquiry form on the right, call us on +44 (0) 1189 817339, or send an email to and we will be happy to assist you with your enquiry.The T24-GW1 is a wireless Modbus gateway that provides a simple interface for users to gather data from up to 100 transmitters in a T24 network. The T24 range of wireless telemetry instrumentation works with any of our wide range of transducers and sensors that we offer and can come calibrated as a complete wireless setup. The T24-GW1 does not support the T24-SAf. It will support all transmitter modules that deliver a single value in their Data Provider packets. Please note: The T24-GW1 will NOT act as a base station and cannot be used to configure T24 modules. TheT24-GW1 wireless modbus gateway comes housed in an IP67 weatherproof enclosure which is suitable for mounting in both indoor and outdoor environments. The T24-GW1 can command the wireless transmitter modules to ‘wake’, ‘sleep’ and ‘stay awake’ if required. The T24-GW1 wireless modbus gateway can provide some simple commands to the wireless transmitters.
The T24-GW1 wireless gateway module has a range of up to 800 metres. The T24-GW1 wireless modbus gateway collects serial data from up to 100 separate T24 wireless transmitter modules in a monitoring system and provides an RS232/RS485 interface using either the Modbus RTU protocol or a simple ASCII protocol to allow users to collect the data with PC, PLC or other SCADA data acquisition system for further analysis.